Knowledge Sharing: Iron Loss and Copper Loss of Transformers

May 06, 2025

Leave a message

Any electrical equipment will experience losses during long-term operation, and power transformers are no exception. In the losses of a power transformer, they are mainly divided into two parts: copper loss and iron loss.

Copper Loss

36020250506163606182

Definition and Principle

36020250506163623075

Copper plays an important role in a transformer. The windings of a transformer usually use copper wires, and the "copper loss" in the transformer is the loss generated by the copper wires. The "copper loss" of a transformer is also called load loss. The so-called load loss is a variable loss and it is changeable. When the transformer is operating under load, there is resistance when the current passes through the wire, resulting in resistance loss. According to Joule's law, when current passes through this resistance, Joule heat will be generated, and the greater the current, the greater the power loss. Therefore, the resistance loss is proportional to the square of the current and has nothing to do with the voltage. It is precisely because it changes with the magnitude of the current that the copper loss (load loss) is a variable loss, and it is also the main loss during the operation of the transformer.

Influencing Factors

 

Current Magnitude: As mentioned above, the copper loss is proportional to the square of the current, so the magnitude of the current is a key factor affecting the copper loss.

 

Winding Resistance: The resistance of the winding directly affects the copper loss. The greater the resistance, the higher the copper loss.

Number of Coil Layers: The more the number of coil layers, the longer the path for the current to flow in the winding, and the resistance will also increase accordingly, resulting in an increase in copper loss.

Switching Frequency: The influence of the switching frequency on the copper loss of the transformer is directly related to the distributed parameters of the transformer and the load characteristics. When the load characteristics and distributed parameters together exhibit an inductive characteristic, the copper loss decreases as the switching frequency increases; when they together exhibit a capacitive characteristic, the copper loss increases as the switching frequency increases.

Temperature Influence: The load loss is also affected by the temperature of the transformer. At the same time, the leakage magnetic flux caused by the load current will generate eddy current loss in the winding and stray loss in the metal parts outside the winding.

Calculation Methods

There are two calculation formulas:

Formula based on rated current and resistance:
Copper loss (unit: kW) = I² × Rc × Δt
Where I is the rated current of the transformer, Rc is the resistance of the copper wire, and Δt is the operating time of the transformer.

Formula based on rated current and total copper resistance:
Copper loss = I² × R
Where I represents the rated current of the transformer, and R represents the total copper resistance of the transformer.

The total copper resistance R of the transformer can be calculated by the following formula:

R = (R1 + R2) / 2
Where R1 represents the copper resistance on the primary side of the transformer, and R2 represents the copper resistance on the secondary side of the transformer.

Methods to Reduce Copper Loss

Increase the cross-sectional area of the transformer winding: Reduce the conductor resistance, thus effectively reducing the copper loss of the transformer.

Use high-quality conductor materials: Such as copper foil or aluminum foil to reduce the resistance of the winding.

Reduce the light-load operation time of the transformer: Limiting the proportion of the light-load operation time of the transformer is beneficial to reducing the copper loss of the transformer.