Photographs of production raw materials
Raw Materials of SCB10-50 Kva 33Kv 3-Phase Resin Insulation Dry-Type Power Transformer
These images present the core raw materials and components of our SCB10-50 Kva 33Kv 3-Phase Resin Insulation Dry-Type Power Transformer, highlighting the precision and quality in our manufacturing process.
High-Quality Resin-Insulated Windings: The red cylindrical components are transformer windings encapsulated with premium epoxy resin. This material ensures superior insulation, moisture resistance, and fire retardancy, laying the foundation for the transformer's safety and durability.
Robust Metal Connectors: Each winding is fitted with sturdy metal connectors, designed for reliable electrical conductivity and mechanical stability, ensuring seamless power transmission.
Large-Scale Production Capacity: The spacious workshop and large quantity of components demonstrate our ability to meet bulk orders while maintaining consistent quality, a testament to our advanced manufacturing capabilities.


Features
The 50KVA power transformer bearing lance for an electrical transformer, a currently considered example of insulation, is particularly effective for electrical insulation and safety. It has three sections and provides a stable and balanced electric current. Dry structures are better suited to the other settings because they are not separated from the oil to minimize the risk of contamination or fires.
Resin Insulation Technology: Adopts high-quality epoxy resin for vacuum casting or encapsulation, ensuring excellent insulation performance, moisture resistance, and dust proofing. It eliminates the risk of oil leakage, making it environmentally friendly and suitable for indoor or harsh working conditions.
Rated Specifications: Operates at a rated capacity of 50 Kva and a primary voltage of 33 Kv, with a three-phase design that meets standard power grid requirements. It delivers stable output voltage and reliable power transmission for industrial, commercial, and infrastructure applications.
Safety & Durability: Features a flame-retardant and self-extinguishing insulation system, complying with international safety standards. The dry-type structure avoids fire hazards associated with oil-immersed transformers, while the robust core and winding design enhance mechanical strength and long-term operational stability.
Efficient & Low Noise: Optimized core lamination and winding layout minimize no-load loss and load loss, ensuring high energy efficiency. Advanced manufacturing processes reduce operational noise, making it ideal for noise-sensitive environments like residential areas, hospitals, or data centers.
Easy Installation & Maintenance: Compact structure and lightweight design simplify transportation and on-site installation. It requires no regular oil replacement or complex maintenance, reducing operational costs and downtime. The transformer also supports convenient monitoring of temperature and performance parameters.
Specifications
|
Parameter |
Details |
|
Capacity |
50 KVA |
|
Voltage |
33KV |
|
Phases |
3 |
|
Insulation |
Resin, dry |
|
Warranty |
10 years |
|
Maintenance |
Every 12 months |
|
Customizable |
Yes |
Advantages
With this 50KVA transformer 3 phase you can guarantee a stable and uninterrupted supply of electricity and minimize the likelihood of power outages and broken equipment. The energy generated by this system will significantly reduce costs. Their space-saving installation gives you more flexibility for planning. A longer lifespan means fewer changes and maintenance, saving you time and money.
High-quality epoxy resin vacuum casting ensures top-tier insulation performance, with strong resistance to moisture, dust, and corrosion. No oil leakage risks-environmentally friendly and safe for indoor use or harsh industrial settings.
50 Kva capacity and 33 Kv primary voltage, paired with a three-phase configuration, deliver stable, reliable power transmission that meets standard grid requirements. Ideal for industrial plants, commercial buildings, and infrastructure projects.
Flame-retardant and self-extinguishing insulation system eliminates fire hazards common in oil-immersed transformers. Complies with global safety standards, offering peace of mind in populated or sensitive areas.
Optimized core and winding design minimizes energy loss, ensuring high operational efficiency and lower electricity costs. Precision manufacturing keeps noise levels low, suitable for hospitals, data centers, and residential neighborhoods.
Compact, lightweight structure simplifies transportation and on-site installation. No regular oil changes or complex maintenance needed-reduces downtime and long-term operational expenses. Easy to monitor temperature and performance for hassle-free management.
Benefits
The 50 KVA 3 phase transformer is efficient and use as much energy as possible in operation, which also reduces the cost of your electricity bill. With its compact and space-saving design that can be easily installed and placed, even in tight spaces. This allows cooling systems to operate reliably even at high temperatures, extending the life of transformers.
Evidence
Our 33KV dry type transformer is used in many industrial and commercial companies, and the response of customers is extremely positive. Independent ratings have found high energy efficiency compared to their products on the market. By using high-quality materials and advanced manufacturing techniques, our transformers can meet our requirements for challenging working conditions and be safe for the long term. For example, in a recent project, more than two years of insulated electrical transformers with more than 50 KVA 33carbonate were installed on triple terminals in a production facility without significant maintenance problems, and significant energy-saving power was achieved.
Actual photos of the finished product


A batch of SCB10-50 kVA 33 kV 3-phase resin-insulated dry-type power transformers has been completed and is ready for shipment overseas.
Q/A section
Q: How often does it require maintenance?
Q: Can it be customized to meet specific requirements?